Category: Practice & Regulation | Estimated reading time: 8 minutes
The Problem with Known Assessments
If a medical laboratory technologist (MLT) knows that the sample they are processing is an assessment sample—not a regular patient sample—there is a high probability that their behavior will change. They may be more careful than usual, double-check work steps, or even subconsciously provide extra attention that does not occur in daily work. This phenomenon makes assessment results biased—measuring the best performance that can be achieved, rather than the actual performance that truly occurs every day.
Blind Samples are specifically designed to avoid this bias.
Definition
A blind sample is a test sample inserted into the routine examination workflow without any special identification, so laboratory staff are unaware that the sample is being evaluated. Its main purpose is to objectively assess the ability of the technician/MLT in performing analytical procedures and to evaluate the overall laboratory system performance without the bias of observation.
Brief History
The concept of blind testing originates from the world of scientific research—including the pharmaceutical field (double-blind clinical trials) and clinical statistics—and was later adapted into medical laboratory quality management as accreditation systems and stricter quality regulations evolved.
In the United States, this momentum aligned with the enactment of CLIA '88 (Clinical Laboratory Improvement Amendments of 1988)—a federal regulation that became the cornerstone of modern clinical laboratory quality management. The CLIA guidance document for Provider-Performed Microscopy procedures explicitly mentions "internal blind testing samples" as one of the official methods to assess test performance—alongside external proficiency testing—as part of the periodic personnel competency assessment requirement.
In global practice, a similar approach is widely known as part of the External Quality Assessment (EQA) scheme—specifically the rechecking method recommended by the WHO for malaria and tuberculosis microscopy, where slides already read by an MLT are sent back "blind" to an expert reader (or conversely, control slides with known values are inserted into the routine examination queue) to assess diagnostic consistency without the reader knowing which sample is being evaluated.
Reason for Use
Blind samples are used to evaluate whether examinations are performed consistently and according to procedures, without the influence of external information or the psychological pressure of knowing they are being assessed. This is crucial in shaping a quality culture and strengthening the integrity of laboratory results—because what is measured is the actual working condition, not the "best" version of work that only appears when supervised.
Advantages
- Assesses the technician's ability objectively and realistically.
- Can identify errors that might not appear under direct supervision.
- Helps detect bias, negligence, or deviations from SOPs that occur under normal working conditions.
- Encourages compliance with work standards under all conditions—not just when feeling supervised.
Disadvantages
- Requires extra planning and oversight to ensure they remain truly "blind"—if discovered, the entire purpose fails.
- If performed too frequently with predictable patterns, technicians may start to notice and recognize the presence of blind samples—reintroducing the same bias as open assessment.
- Not always effective if not followed up with results evaluation—a blind sample whose results are merely archived without coaching provides no added value.
- Requires good logistical control to differentiate blind samples from patient samples—including a neat coding system to ensure they are not swapped or do not interfere with actual patient workflows.
Data Required
- Internal sample identification data—special codes known only to the evaluator, not the staff performing the test.
- Target value or the true result of the blind sample.
- Technician's test result data without prior intervention or notification.
- Records of the process and everyone involved in the examination.
How to Use
- Prepare samples that are identical to routine samples but assign them a secret internal code.
- Insert the samples into the routine workflow without notifying the technician.
- Once the examination is complete, evaluate the results and compare them with the true values.
- If there is a deviation, conduct a root cause analysis and provide coaching if necessary.
Technical note: the evaluation of results in step 3 is essentially the calculation of d% (percent deviation)—the same concept already discussed in the Accuracy, Precision & Monthly Evaluation article. The difference here is that it is not the QC material results being evaluated, but the work results of a specific MLT for one particular sample. Since the calculation is identical to what already exists, blind samples do not require a new calculator—simply use the same d%/TE evaluation approach against the target value of the blind sample.
Suitable for Use When
- Performing internal audits of laboratory technician competency.
- Periodically evaluating laboratory performance (e.g., quarterly).
- Following the training of new technicians, to ensure practical ability—not just theoretical knowledge from training.
- Validating the entire laboratory system—including assessing whether the whole workflow (not just one person) is running according to standards.
Closing
A blind sample is a hidden assessment method that is highly effective in measuring technician performance and laboratory system integrity in real-life situations. By eliminating psychological bias resulting from direct supervision, this method provides a more accurate reflection of actual practice in the field—compared to merely assessing performance when it is known that an evaluation is taking place.
Although it requires careful management and planning, a blind sample program can detect potential deviations and increase quality awareness among laboratory staff. When used periodically and accompanied by constructive feedback—not merely punishment, but coaching—this instrument will significantly support continuous quality improvement, in line with the CAPA (Corrective and Preventive Action) principles discussed in the Six QA Components article.